- TECHNICAL CHARACTERISTICS
- Wall-mounted, through-the-wall type units
- Electronic control panel.
- Expansion device: capillary tube.
- Hot gas defrost.
- Cold room lighting: units are only pre-arranged for a cold room lighting connection.
- Cable for door switch connection; door switch functions can be programmed on the electronic control panel.
- Cable for door heater connection on all low temperature units.
- Crankcase heater on compressors.
- All forms are equipped with adjustable low and high pressure switches with automatic reset.
- Suction accumulator.
- Supplemental solenoid valve.
- Condenser fan pressure switch.
- Direct drainage of condensate.
- Drain heater on all medium and low temperature units.
- Units recommended for use at ambient temperatures not lower than 10°C.
- Suitable accessories are required for use at temperatures below 10°C. In case of outdoor installation it is necessary to protect them from the weather.
Optionals:
Special voltage.
Water-cooled condenser: units equipped with water-cooled condenser are also provided with a pressure controlled water valve, a fixed calibration high pressure switch (even on single-phase units), as well as a compressor cooling fan (low temperature units only).
Remote panel: already connected to the unit and provided with a 5 metres long cable (on request extension up to 20 metres).
Voltage monitor.
Condenser fan speed regulator.
Switchboard heater.